1 … * |
M |
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:templateId
|
|
II |
1 … 1 |
M |
|
(BCLaboratoryBatteryOrganizer) |
 |
 |
@root
|
|
uid |
1 … 1 |
F |
1.3.6.1.4.1.19376.1.3.1.4 |
 |
hl7:id
|
|
II |
0 … * |
R |
The organizer identifier MAY be present. |
(BCLaboratoryBatteryOrganizer) |
 |
hl7:code
|
|
CE |
0 … 1 |
|
The unique battery test code from an international standard, such as LOINC, MAY be
present. This is different from [1.3.6.1.4.1.19376.1.3.1.6|Laboratory Observation],
where it is required.
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:statusCode
|
|
CS |
1 … 1 |
M |
The test status SHALL be either "completed", "aborted", or "obsolete". A status of
completed means the all expected results are present. A status of aborted means at
least one or more of the tests could not be performed and has no result, some results
may be present. A status of obsolete means the battery has been replaced by a newer
battery (following it) in this revision of the report.
|
(BCLaboratoryBatteryOrganizer) |
|
CONF |
@code shall be "completed" |
or |
@code shall be "aborted" |
or |
@code shall be "obsolete" |
|
 |
hl7:effectiveTime
|
|
TS |
0 … 1 |
|
The battery's relevant clinical time (ideally specimen collection time) MAY be present. |
(BCLaboratoryBatteryOrganizer) |
 |
hl7:specimen
|
|
|
0 … 1 |
|
A Laboratory Battery Organizer MAY contain the <specimen>, typeCode="SPC" when it
is different from the one documented at a higher level, including the header.
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:performer
|
|
|
0 … 1 |
|
A Laboratory Battery Organizer MAY contain the person who performed the entire battery
when it is different from the one documented at a higher level, including the header.
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:author
|
|
|
0 … * |
|
A Laboratory Battery Organizer SHALL contain author(s) of the Laboratory Battery when
multiple header author(s) exist and not all apply to this Laboratory Battery. The
author/time element carries the date&time the laboratory report was produced by the
system.
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:participant
|
|
|
0 … 1 |
|
A Laboratory Battery Organizer MAY contain up to 3 types of participants "AUTHEN",
"RESP", and "DEV".
- AUTHEN: The verifier of the battery organizer. In the case where a laboratory report
has multiple verifiers. Each verifier is attached to the subset of batteries/observations
he or she verified, by the means of a <participant> element.
- RESP: The person responsible for the provision of the battery. In the case where this
battery is subcontracted to an external laboratory, this external laboratory (with
its address and telcom) and the actual performer is represented by a <performer> element,
whereas the Director of this subcontractor laboratory is carried by the <participant>
element being attached to the same level as the <performer> element.
- DEV: A device or equipment, which was used to produce this battery of results (e.g.
an analyzer).
|
(BCLaboratoryBatteryOrganizer) |
 |
hl7:component
|
|
|
1 … * |
M |
The Laboratory Observations performed in the battery. A Laboratory Battery Organizer
SHALL have at least one Laboratory Observation. Contains 1.3.6.1.4.1.19376.1.3.1.6 Laboratory Observation (DYNAMIC)
|
(BCLaboratoryBatteryOrganizer) |
where [hl7:observation [hl7:templateId/@root='1.3.6.1.4.1.19376.1.3.1.6']] |
|
 |
 |
@typeCode
|
|
cs |
0 … 1 |
F |
COMP |
 |
hl7:component
|
|
|
0 … 1 |
R |
The Battery Organizer comment using the Annotation Comment template. Contains 1.3.6.1.4.1.19376.1.5.3.1.4.2 BC Annotation Comment (DYNAMIC)
|
(BCLaboratoryBatteryOrganizer) |
where [hl7:act [hl7:templateId/@root='1.3.6.1.4.1.19376.1.5.3.1.4.2']] |
|
 |
 |
@typeCode
|
|
cs |
1 … 1 |
F |
COMP |